CPX-CEC-C1-V3 (3473128) control block

OT-FESTO058739

Exemplary representation: CPX-CEC-S1-V3 (3472425)   &   CPX-CEC-C1-V3 (3473128)
795,58€ incl. VAT
pcs
{{ $t('shop.display.artikel.hinweis_alternative') }}
{{ $t('shop.display.artikel.eigenschaften_headline') }}
Dimensions W x L x H 50 mm x 107 mm x 55 mm
Parameterising CODESYS V3
Additional functions Diagnose functions,
Motion function for electrical actuators
Operating element Rotary switch for RUN/Stop,
DIL switch for CAN connection
Intrinsic power input at operating voltage type 85 mA
Nominal operating voltage DC [V] 24
Power blackout bridging [ms] 10
Corrosion resistant class KBK 2 - moderate corrosion stress
Bearing temperature [°C] -20 to 70
Protection category IP65,
IP67
ambient temperature [°C] -5 to 50
Product weight [g] 135,0
Report CODESYS Level 2,
EasyIP,
Modbus TCP,
TCP/IP
Material information RoHs compliant
Housing material PC,
PA reinforced
Device specific diagnosis Diagnose-Speicher,
Kanal- und modulorientierte Diagnose,
Unterspannung/Kurzschluss Module
Configuration support CODESYS V3
LED display bus specific TP: Link / traffic
LED display product specific ERR: Runtime error PLC,
M: Modify/force active,
PL: Load supply,
RUN: PLC status,
SF: System error,
STOP: PLC status,
PS: Electronics supply, sensor supply
CPU data 32 MB flash,
256 MB RAM,
Processor 800 Hz
Programming, operating language DE, EN
Programming, support file handling yes
Processing time approx. 200 µs/1 k instruction
Setting IP address DHCP,
over MMI,
over CoDeSys
Functional building block CPX diagnosis status,
CPX copy diagnosis trace,
CPX read module diagnosis,
and other
Marker Variable concept CoDeSys,
28 kB residual data
Nominal operating voltage DC load voltage 24 V,
With pneumatic type Midi/Maxi: 21.6 ... 26.4V,
With pneumatic type CPA: 20.4 ... 26.4V,
With pneumatic type MPA: 18 ... 30V,
Without pneumatic: 18 ... 30V
Programming software CODESYS provided by Festo
Programming language Instruction list (AWL),
Contact diagram (KOP),
acc. to IEC 61131-3,
Sequence language,
Function plan,
Structured text,
Additional CFC
Programming memory 16 MB user program
Relative humidity 95 %,
Not condensing
Ethernet, number 1
Ethernet, data transfer speed 10/100 Mbit/s
Ethernet supported protocols TCP/IP, EasyIP, Modbus TCP
Ethernet, connection plug RJ45,
8 pin,
Bushing
Ethernet interface RJ 45 (jack, 8-pin)
Total number of axes 127
Fieldbus interface, galvanically separated yes
Fieldbus interface, transfer rate 125, 250, 500, 800, 1000kbit/s,
can be set via software
Fieldbus interface, connection technology Sub-D,
9 pin,
Plug
Fieldbus interface CAN bus
Control interface CAN bus
OT-FESTO058739
{{ $t('shop.all.gewicht') }} 135,0 g / pcs
{{ $t('shop.display.artikel.zollwarennummer') }} 85371091
{{ $t('shop.all.hersteller') }} Festo
{{ $t('shop.all.dokumente') }}
    Documentation festo/datenblaetter/3473128_en.pdf
    Group data sheet: CPX-CEC-V3 (english) festo/gruppendatenblaetter/cpx-cec-v3_en.pdf
    Group data sheet: CPX-AB-2-M12 (english) festo/gruppendatenblaetter/cpx-ab-2-m12_en.pdf
  • {{ $t('shop.display.datenblatt.titel') }} (Print view)

 
{{ $t('shop.all.unverbindliche_richtwerte') }}
{{ $t('shop.all.spaetbestellservice') }}
{{ countdownAsString }} {{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }}
{{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }} {{ countdownAsString }}

{{ $t('shop.all.spaetbestellservice.hinweis') }}

{{ $t('shop.all.wochenendversand') }}
{{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }} {{ countdownAsString }}

{{ $t('shop.all.wochenendversand.hinweis') }}

An error has occurred!

An error has occurred, please reload this page and try again.